Outdoor padel court enclosed by tempered glass panels and mesh fencing
Built to FIP standards and TTF adequacy criteria

Padel Court Construction and Cost

Surface, glass, structure and lighting are priced separately and in Turkish Lira. The final figure is set by a written quote after the site and subgrade survey.

20 × 10 m FIP internal dimensions 12 mm Tempered glass thickness 3 mm under a 3 m straightedge Surface flatness tolerance 4 – 6 years Typical payback period
12 mm Glass thickness scoring full marks in the TTF assessment
6 m Minimum clear ceiling height on an indoor court
504 m² Recommended total area for a single court
%1 Maximum cross fall on an undrained surface
Standards we build to FIP Rules of Padel TTF Sporting Adequacy Criteria TS EN 12150 Tempered Glass Standard TS EN 12193 Sports Lighting Standard

Pricing

Padel Court Prices 2026

The bands below cover turnkey construction and are based on a single court. Land cost, permit fees, landscaping and transport are excluded.

Last updated: August 2026

Outdoor padel court with stepped glass side walls and galvanised steel structure

Outdoor standard court

⁦700.000 – 1.000.000 ₺⁩

  • Galvanised steel structure
  • 10 mm tempered glass, stepped side wall
  • Artificial turf surface in FIP dimensions
Request a Quote
Most frequently chosen
Panoramic padel court with an uninterrupted glass side wall

Outdoor panoramic court

⁦900.000 – 1.300.000 ₺⁩

  • Stepless 3 × 4 m glass side wall
  • 12 mm tempered glass, 8 / 8 in the TTF assessment
  • LED lighting included
Request a Quote
Indoor padel court under a tensile membrane roof

Indoor court, membrane roof

⁦1.300.000 – 1.900.000 ₺⁩

  • Tensioned membrane roof system
  • Minimum 6 m clear height
  • Suitable for year round use
Request a Quote
Indoor padel facility with steel load bearing structure and roof cladding

Indoor court, sandwich panel

⁦1.900.000 – 2.900.000 ₺⁩

  • Steel framed building
  • 8 m and above, 6 / 6 in the TTF assessment
  • Insulated and suitable for climate control
Request a Quote

The figures above are starting bands and do not constitute a binding quote. The final figure is set by a written quote after the site and subgrade survey.

Detailed cost breakdown for an indoor facility with several courts

Why the prices are published in Turkish Lira

Padel court prices are usually published in euro. That approach leaves the entire exchange rate risk with the buyer and makes quotes hard to compare.

On this page the bands are given in Turkish Lira only. No foreign currency equivalent is published. The rate changes daily and a figure printed on the page becomes wrong within a short time. The bands are reviewed every three months and the date of the last update is stated visibly on the page.

The figures are given as bands for the same reason. A single amount would not be realistic, because steel, tempered glass and artificial turf are priced in separate markets. Which end of the band applies is determined after the site and subgrade survey.

Items outside the bands

Two quotes can only be compared at the same scope. The items below are not included in the bands above and are calculated separately after the survey.

  • Land cost and demolition of any existing structure on the plot
  • Permit fees, engineering and professional signature charges
  • Changing rooms, showers, reception and plant areas
  • Car park, landscaping and perimeter lighting
  • Transport, crane hire and accommodation for the installation crew
  • Mains electricity connection and distribution board upgrades

Six variables that set the price

Where the difference between two quotes comes from is rarely written down. The cost of a padel court is set by the six items below.

  1. Court model

    The stepped standard system needs less tempered glass and a lighter structure than the stepless panoramic system. The panoramic system uses 3 × 4 m uninterrupted glass in the end zones.

  2. Roof solution

    An outdoor court forms the lowest band. A membrane roof allows year round use, while a sandwich panel building adds insulation and climate control and sets the upper end of the band.

  3. Surface grade

    Pile height, fibre type and stitch density of the artificial turf determine both playing performance and cost. The gap between the economy grade and the tournament grade can exceed a factor of two per square metre.

  4. Lighting

    Fixture count, pole height and driver quality affect the cost directly. The lower face of the floodlight is positioned at least 6 m above the surface.

  5. Number of courts

    When several courts are built on the same site, transport, crew time and groundwork are shared. The cost per court therefore falls.

  6. Location and logistics

    Haulage distance, vehicle and crane access to the plot and crew accommodation all affect the cost. Restricted access also extends the installation period, and that is reflected in the quote.

Cost items

What this figure pays for

The breakdown below covers an outdoor standard court and consists of six items. Each item has its own range.

  • Groundwork, levelling and concrete base ⁦27.000 – 110.000 ₺⁩
  • Structure, glass panels and mesh fencing ⁦439.000 – 823.000 ₺⁩
  • Surface covering, artificial turf and silica sand ⁦110.000 – 219.000 ₺⁩
  • Lighting and electrical installation ⁦110.000 – 220.000 ₺⁩
  • Equipment, net, posts and accessories ⁦27.000 – 55.000 ₺⁩
  • Labour, transport and installation ⁦55.000 – 165.000 ₺⁩

The upper ends of the items do not occur at the same time. Because each item has its own independent range, adding all six upper ends exceeds the product band. On one project the groundwork may sit at the upper end while the equipment stays at the lower end. The purpose of the breakdown here is not to verify the total but to show which items the figure is made of.

Technical summary

Court dimensions, internal
20 × 10 m
Dimensional tolerance
%0,5
Net, centre and ends
0,88 m / 0,92 m
Service line distance
6,95 m
Line width
5 cm
Back wall, glass and mesh
3 m / 1 m
Flatness tolerance
3 mm under a 3 m straightedge
Cross fall, undrained
%1

Source: FIP Rules of Padel, in force from 01.01.2026

Get a clear figure for your project

The survey is free, carries no obligation and turns into a written quote within twenty four hours.

Message Us on WhatsApp Request a Padel Court Quote

Calculator

Padel Court Cost Calculator

Four selections produce a band derived from market data. The result can be carried straight into a written quote request or a WhatsApp message. The calculation runs in the browser and no data is transmitted; sharing the result remains entirely the user decision.

Lighting is already inside the band for indoor courts and the panoramic system.

Approximate cost

⁦900.000 – 1.300.000 ₺⁩

Outdoor panoramic court · 1 courts · Mid grade in FIP dimensions

What this estimate includes
Galvanised steel structure, tempered glass panels and mesh fencing, artificial turf surface, silica sand infill, net and posts, labour and installation are included in this estimate. Land cost, permit fees, landscaping, transport and buildings outside the court are excluded.

This tool produces an estimate and does not replace a quote. The final figure is set by a written quote after the site and subgrade survey.

Investment

How Many Years Does a Padel Court Take to Pay Back

The first question an investor asks is not what the cost is, but when the cost comes back. The tool below answers that with an explicit model and states the limits of that model.

The default value covers electricity consumption only. Rent, staff, tax and maintenance must be added to this field.

Gross payback on the court investment

⁦0,6 – 0,8 years⁩

This figure is gross and covers the court investment only. The real payback period is not visible until rent, staff, tax and maintenance are entered into the operating cost field.

Court investment
⁦1.710.000 – 2.470.000 ₺⁩
Monthly gross revenue
⁦273.000 ₺⁩
Monthly operating cost
⁦23.000 ₺⁩
Monthly net
⁦250.000 ₺⁩
Let Us Discuss Your Investment Plan

What this figure covers and what it does not

The amount calculated is the investment in the court itself. Land cost, buildings, changing rooms, reception, car park and landscaping fall outside it.

Only electricity consumption is preset in the operating cost field. If rent, staff, tax, insurance and maintenance are not added, the payback period appears shorter than it is.

The result is therefore not facility depreciation but the gross payback on the court investment. The period expected for a complete facility is given separately below.

The model excludes tax, depreciation and financing cost. In a debt financed investment the interest burden extends the payback period, and that effect belongs in the operator own accounts.

Occupancy is taken as a single value for the whole year. In practice occupancy varies by season and by day of the week, and it falls noticeably on outdoor courts in winter.

What the Turkish market shows against the industry claim

The industry frequently states that a padel court investment pays back within twenty four to thirty six months. Operating data published at the scale of Turkey does not confirm that period.

The large majority of successful facilities recover the investment within four to six years. The conservative figure is the one published on this page. Promising an investor two years and delivering five is the most expensive error that can be published.

Short payback claims usually count the court cost alone and assume full occupancy. When land, buildings, staff and tax are added to the same calculation, the period more than doubles.

The difference comes from facility scale. The table below shows published initial investments alongside the number of courts and makes the distance between court cost and facility cost visible.

The table also shows the effect of scale. As the number of courts rises, the amount per court falls, because groundwork, lighting infrastructure and landscaping are one off items.

Assumptions behind the model

The period returned by the calculation rests on the constants below. An investor holding actual operating data can enter those values into the fields and reproduce the result.

Monthly capacity
Monthly capacity per court is taken as 420 hours. That value represents an operating window spread across the whole day and averages weekdays with weekends.
Occupancy rate
Three scenarios are offered and the realistic one is taken as sixty five per cent. Newly opened facilities run below that rate for the first six months.
Hourly rate
The preset rate comes from the range commonly seen for court rental across the country. City centre and indoor courts operate near the upper end of that range.
Operating cost
The preset cost covers electricity consumption only. Rent, staff, tax, insurance and maintenance must be added from the operator own data.

Initial investment by facility scale

Facility type Courts Initial investment Per court
Outdoor courts, leased land 2 ⁦2.500.000 – 4.500.000 ₺⁩ ⁦1.250.000 – 2.250.000 ₺⁩
Indoor courts, leased land 2 ⁦5.000.000 – 9.000.000 ₺⁩ ⁦2.500.000 – 4.500.000 ₺⁩
Indoor courts with social areas, owned land 4 ⁦12.000.000 – 22.000.000 ₺⁩ ⁦3.000.000 – 5.500.000 ₺⁩

The amounts are compiled from initial investment ranges disclosed in industry publications. The court cost sits inside those amounts and forms only part of the total. Land cost is excluded for facilities built on owned land, while rent on leased land belongs in the operating accounts.

Building area and item by item investment for an indoor facility

Dimensions

Padel Court Dimensions and the FIP Standard

Court dimensions are defined in the rule book of the international padel federation and admit no interpretation. Every value below is taken from that source.

Padel court plan drawing The internal dimensions of the court are twenty metres by ten metres. The net divides the court in the middle. Service lines are drawn six metres ninety five centimetres from the net axis. The centre service line divides the service box in two. net 20 m 10 m 6,95 m

Dimensions are measured between the internal faces of the court. Wall thickness falls outside them.

The rule book defines the internal dimensions as 20 × 10 m and allows a tolerance of %0,5. That tolerance corresponds to ten centimetres in length and five centimetres in width. The two halves of the court must be perfectly symmetrical.

The net is 10 m long, 0,88 m high at the centre and 0,92 m high at the ends, with a tolerance limited to 5 mm. The maximum height of the side posts is set at 1,05 m. The outer face of the posts coincides with the lateral boundary of the court.

Service lines are drawn 6,95 m from the net axis and parallel to it. The centre service line divides the area between the net and the service line and extends at least twenty centimetres beyond the service line. Every line is 5 cm wide without exception.

Line colour is chosen to contrast with the surface, preferably white or black. The surface is a single colour throughout and is clearly distinct from the wall colour. The rule book permits green, blue or terracotta for the surface.

Dimensions are taken between the internal faces of the court. Wall thickness falls outside them and is added separately to the land calculation. The most common error in practice is treating the external dimension as the internal one.

Deviation in dimensions maps directly onto the federation assessment. Full compliance scores full marks and a deviation of up to five centimetres is scored partially. A non standard dimension scores zero and leads to the certificate being withheld.

Enclosure structure and heights

4 m

Back walls

The lower section is a wall 3 m high and may be transparent or solid. The upper section is metal mesh 1 m high.

3 m × 2 m

Side wall, stepped

A two step wall is placed at each end. The first step measures 3 m × 2 m and the second 2 m × 2 m.

3 × 4 m

Side wall, panoramic

A single stepless pane is used in the end zones. That is the definition of panoramic, and it is not a marketing adjective.

5 – 7,08 cm

Mesh specification

The mesh diagonal falls within 5 – 7,08 cm. Wire thickness of 2 – 3 mm is recommended and does not exceed 4 mm. The layout rule is explicit: horizontal wires inside, vertical wires outside.

6 m

Clear height

A clear height of at least 6 m is required across the whole court. The value recommended for new facilities is 8 m.

1,05 × 2,00 m

Court accesses

Accesses are placed on the sides and symmetrically about the centre. With a single access the opening falls between 1,05 × 2,00 m and 2,20 × 2,20 m.

0,72 × 2,00 m

Access, two sided layout

With two accesses each opening falls between 0,72 × 2,00 m and 1,10 × 2,20 m. Where doors are fitted, the handles sit on the outside and do not protrude inwards.

3 m

Safety area

A clear area of at least 3 m is required outside the court and 4 m is recommended. The clear height of that area is 3 m.

2 cm

Access protection

Access edges, the upper section and the net post are covered with impact absorbing material at least 2 cm thick. Foam, rubber and neoprene are used for this purpose.

A single player court dimension is not defined in the rule book. The twenty metre by six metre dimension commonly used in the market is an industry convention and not a federation rule.

Every value in this section is taken from FIP Rules of Padel and came into force on 01.01.2026.

Land

How Much Space Does a Padel Court Occupy

The court itself occupies 200 m². The land required for construction is more than twice that figure. The difference is set by the safety area.

The rule book requires a clear safety area on all four sides of the court. That area is at least 3 m wide and 4 m is recommended. Its clear height is also at least 3 m.

At the minimum dimension the total area is 26 × 16 m, that is 416 m². At the recommended dimension it becomes 28 × 18 m, that is 504 m². The gap between court area and land requirement therefore exceeds a factor of two and a half.

In the adequacy assessment of the Turkish Tennis Federation, the out of court area per court is a separate criterion. An area above 4 m and judged safe scores full marks. Between three and four metres it is scored partially.

Reception, changing rooms, showers, plant rooms and car parking fall entirely outside this calculation. In facilities with several courts the shared areas reduce the land requirement per court to some degree.

Before dimensions, land selection considers level difference, drainage and vehicle access. These three items are measured on site during the survey and the quote is finalised accordingly.

Court orientation is as decisive as dimensions. Keeping the long axis close to the north and south line reduces sun in the players line of sight during morning and evening hours.

Ground level and surrounding water flow determine the real cost of a plot. A sloping plot may require retaining walls or fill. That item falls outside the court cost and is calculated separately during the survey.

Vehicle access is overlooked in most assessments. Glass panels and steel sections arrive on long vehicles. On a plot where a crane cannot be positioned, both installation time and cost increase.

Court area and land requirement plan A clear safety area surrounds the court on all four sides. The inner rectangle shows the court and the outer rectangle the recommended total area. Court Safety area 28 m 18 m

Area calculation

Court internal dimensions
20 × 10 m
Court area
200 m²
Safety area, minimum
3 m
Safety area, recommended
4 m
Total area, minimum
26 × 16 m
Total area, recommended
28 × 18 m

The values apply to a single court. Social areas and car parking are excluded.

Items measured during the land survey

A plot that satisfies the dimensional requirement is not sufficient on its own. The five items below are measured on site during the survey and affect the quote directly.

Level difference
The difference between the highest and lowest point of the plot is measured. As that difference grows, excavation, fill and retaining items come into play and groundwork cost rises.
Bearing capacity
The foundation solution is determined by the bearing capacity of the ground. On made ground the foundation depth increases, the concrete volume grows and the schedule lengthens.
Drainage outfall
Where rainwater will discharge is established at the outset. A distant outfall creates a separate drainage line item that is added to the quote.
Vehicle and crane access
Access for long vehicles and a crane position are checked. On plots with restricted access the installation period lengthens and additional equipment is required.
Power connection
The distribution board capacity required for lighting and the distance to the existing connection point are measured. A distant connection creates cabling and ducting items.

Systems

Standard, Panoramic and Indoor Court Comparison

The difference between the four systems starts with the glass structure and extends to cost, installation time and adequacy score. The table below places all four on the same row.

System Glass structure Price band Installation TTF glass score
Outdoor standard court Stepped, 10 mm ⁦700.000 – 1.000.000 ₺⁩ ⁦3 – 5 weeks⁩ 5 / 8
Outdoor panoramic court Stepless 3 × 4 m, 12 mm ⁦900.000 – 1.300.000 ₺⁩ ⁦3 – 5 weeks⁩ 8 / 8
Indoor court, membrane roof Stepless 3 × 4 m, 12 mm ⁦1.300.000 – 1.900.000 ₺⁩ ⁦6 – 9 weeks⁩ 8 / 8
Indoor court, sandwich panel Stepless 3 × 4 m, 12 mm ⁦1.900.000 – 2.900.000 ₺⁩ ⁦10 – 14 weeks⁩ 8 / 8

Installation time covers the period from subgrade preparation to handover. The permit process falls outside it. The TTF glass score in the table reflects the glass criterion alone. The total adequacy score is calculated from all nine technical criteria and is set out in the regulation section.

Building, HVAC and operating cost breakdown for an indoor hall

Panoramic system, stepless 3 × 4 m glass in the end zone

The rule book permits two variants for the side wall. In the stepped system a two step wall is placed at each end; the first step measures 3 m × 2 m and the second 2 m × 2 m. In the panoramic system 3 × 4 m of uninterrupted glass is used in the end zone and there are no steps.

That is why the panoramic system costs more. A single pane requires both more tempered glass and a stronger structure. Because the spectator view remains uninterrupted, tournament and club facilities prefer this system.

A larger glass surface does not only increase material cost. As panel weight rises, the structural section, the number of fixings and the foundation load grow with it. The cost difference between the two systems is the sum of those three items.

The stepped system does not change the rules of play and is suitable for official competition. The difference is commercial and visual rather than sporting. In coaching and membership driven operations the stepped system lowers the investment and shortens the payback period.

Indoor system, membrane roof and minimum 6 m clear height

In indoor systems the roof solution is decisive. A tensioned membrane roof is installed faster and provides year round use at a lower cost. A sandwich panel building brings thermal insulation and climate control, while installation time and cost both increase.

The life of a membrane cover depends on the fabric grade and on tension maintenance. The cover is re tensioned at intervals and the seams are inspected regularly. A sandwich panel has no such maintenance item, but its initial cost is markedly higher.

Climate is as decisive as the plot when choosing an indoor system. In provinces with high snow loads the roof structure is calculated separately and the cover options narrow. In temperate regions rain and wind protection is sufficient for most operators.

On an indoor court the ceiling height affects the certificate directly. In the federation assessment 8 m and above scores full marks, while between 6 m and 8 m scores partially. A height below 6 m scores zero and leads to the adequacy certificate being withheld. This is the most common error in tent and hangar conversions.

In an indoor facility ventilation and heating form a separate item and are not included in the court cost. The federation instruction requires the sports area temperature to stay at or above 18 °C. That condition shapes both the building envelope and the operating cost.

Conditions that determine the system choice

The table shows the numeric difference between the four systems. The cards below summarise which system is chosen under which conditions.

Outdoor standard system

Preferred where the investment figure is decisive and the operation is driven by coaching and memberships. It has the shortest installation period.

Lowest investment figure

Outdoor panoramic system

Used in facilities planning tournaments, spectators and video recording. The uninterrupted glass surface also earns an advantage in the federation assessment.

Tournaments and spectator layout

Indoor system, membrane roof

Suits operators seeking year round use who also want to keep the installation period short. Insulation requirements are limited.

Fast installation, year round use

Indoor system, sandwich panel

Chosen where thermal insulation, climate control and a permanent building are required. It has the highest investment figure and the longest installation period.

Insulated permanent building

Materials

Glass, Structure and Surface Specification

The cost difference between two quotes usually comes from the material grade. The items below can be asked about directly when quotes are compared.

Glass and mesh junction, installation stage

Tempered glass

Glass thickness determines the certificate

In the federation adequacy assessment, the glass thickness scoring 8 / 8 when certified and gap free is twelve millimetres. Ten millimetre tempered glass is scored 5 / 8 under the same conditions. Uncertified or gapped glass scores zero and on its own leads to the certificate being withheld.

That is the first question to ask when comparing quotes. If the glass thickness is not stated in the written quote, the two quotes may not describe the same work.

Thickness alone is not a sufficient criterion. Of two panels of the same thickness, one that did not leave the tempering furnace evenly shows optical distortion and fails earlier under load. The compliance of the panel with the standard is therefore requested with a manufacturer certificate.

The section of the supporting profiles and the number of fixings per panel also affect the cost. Where the structure is inadequate the glass oscillates over time and cracks start at the corner junctions. That is where the difference between two apparently identical walls appears.

Whether a broken panel can be replaced on its own depends on the installation layout. In systems where neighbouring panels share a fixing, replacing one panel requires part of the wall to be dismantled. That detail rarely appears in a written quote and is discovered during operation.

  • Tempered glass complies with the TS EN 12150 standard
  • The wall surface is uniform, rigid and completely flat
  • At most one logo is placed per wall
  • Panel edges are ground and do not protrude into the playing area
  • Glass junctions are covered with a protective profile

Galvanised steel sections, before assembly

Structure

Galvanised steel frame and mesh fencing

The load bearing system is produced from hot dip galvanised steel. On an outdoor court corrosion resistance determines service life directly, so the coating thickness should be sought in the quote.

The difference between hot dip galvanising and painted steel is invisible in the first year. It appears after the third year in humid and salt laden environments. Coating thickness is a value given in microns and is requested as a number in the written quote.

All welded fabrication is completed in the production facility and galvanising follows welding. Every section cut or drilled on site breaks the coating. Unless those points are sealed with a zinc based repair material, corrosion starts in the first winter.

Post spacing and section size are determined by wind load. On an outdoor court the glass forms an uninterrupted screen, so the structural calculation differs from an indoor court. Sections are increased on elevated or exposed plots.

The mesh diagonal falls within 5 – 7,08 cm. Wire thickness of 2 – 3 mm is recommended and does not exceed 4 mm. The layout rule is explicit: horizontal wires inside, vertical wires outside. The tensioning mechanism is positioned outside the court and protected.

The mesh layout is a safety rule rather than a visual preference. If vertical wires sit on the inside, the wire ends face the playing area and ball rebound becomes irregular. For the same reason the tensioning device is moved to the outer face of the court.

  • Welded joints are protected on both faces
  • The mesh is always aligned with the inner face of the wall
  • Where welded unwoven mesh is used, the aperture is square
  • Galvanised coating thickness is stated in microns in the quote
  • Sections worked on site are sealed with a zinc based material

Artificial turf fibre and silica sand infill

Surface

Artificial turf, sand infill and the colour rule

The surface may be concrete, a synthetic material or artificial turf. On artificial turf the pile height, fibre structure and stitch density determine both playing performance and cost. Silica sand infill holds the fibres upright and regulates ball rebound.

Artificial turf is produced with two main fibre types. Monofilament fibre gives a more consistent bounce and holds the sand infill longer. Fibrillated fibre costs less and flattens sooner under heavy use.

The quantity of sand determines the behaviour of the surface directly. Insufficient infill makes the ball bounce higher than expected, while excess infill causes underfoot slipping and flattens the fibres. Infill is spread in stages and brushed after each stage.

Roll seams must not be perceptible in the playing area. Seams are joined with bonding tape and no level difference is left at the junction. A lifting seam disrupts rebound and creates a trip hazard.

The rule book permits green, blue or terracotta for the surface colour. The surface is a single colour throughout and is clearly distinct from the wall colour.

  • Flatness tolerance does not exceed 3 mm under a 3 m straightedge
  • Maximum cross fall on an undrained surface is %1
  • Line width is 5 cm without exception
  • Seams create no level difference in the playing area
  • A surface certificate is separately required in the federation assessment

Net layout and access opening, outdoor court

Net and equipment

Net, access opening and safety area

The net divides the court into two equal halves and is 10 m long. Its height is 0,88 m at the centre and 0,92 m at the ends. A deviation of 5 mm is accepted on both values and the post height is set at 1,05 m.

The net is a separate criterion in the federation assessment. Correct heights alone are not sufficient; the absence of a gap between the post and the side wall is also required. The tensioning mechanism sits outside the court and is protected against contact during play.

Accesses are opened on the sides and symmetrically about the centre. In a single access layout the opening stays between 1,05 × 2,00 m and 2,20 × 2,20 m. In a two access layout each opening measures between 0,72 × 2,00 m and 1,10 × 2,20 m.

Where out of court play is to be allowed, two access points are required on each side. The rule book requires a clear area of at least 3 m outside the side walls and recommends 4 m. That area is kept clear up to a height of 3 m.

  • Net height is verified by measurement after installation
  • Door handles sit on the outside and do not protrude inwards
  • Access protection is covered with impact absorbing material at least 2 cm thick
  • No poles, trees or pits are present in the safety area

Lighting

Lighting Is Measured in Lux, Not in Watts

Most quotes in the market describe lighting in watts. Watts state only the electricity consumed. The brightness a player actually sees is measured in lux.

LED floodlight layout, night use

Values given by the rule book

Floodlight lower face, minimum
6 m
Recommended when court mounted
8 m
Television broadcast, vertical
1000 lux
Pole position
outside the court

A watt is a unit of consumption and says nothing about how much light reaches the surface. Two fixtures of the same wattage produce entirely different illuminance on the court if their optics and positions differ. The question to ask when comparing quotes is not the wattage of the fixture but the lux measured on the court surface.

The rule book requires the lower face of the floodlight to sit at least 6 m above the surface. Where lighting is to be mounted within the vertical projection of the side walls, 8 m is recommended for new facilities. Poles are positioned outside the court; if one falls inside the safety area, out of court play is prohibited.

Light must be distributed evenly and must not impair the view of players, officials or spectators. Facilities intended for television broadcast or filming require at least 1000 lux of vertical illuminance.

Lighting is a separate criterion in the federation adequacy assessment. A shadow free LED layout with no intrusion into the court scores full marks. Lighting that is merely playable is scored partially.

The number and position of fixtures determine how evenly light reaches the surface. A small number of powerful fixtures may deliver the total illuminance yet leave dark zones in the corners, causing players to pick up the ball late.

Colour rendering is also part of the design. At low colour rendering a yellow ball does not separate sufficiently from the surface colour. In facilities with heavy night use that detail affects playing quality directly.

Values we do not publish

The lux classes frequently quoted for training, national and international level do not appear in the rule book. Those values come from secondary sources and are not published on this page until they are verified against the primary text. Only the height and broadcast figures given explicitly by the rule book appear here.

Four items required in a lighting quote

The wattage of a fixture is not a commitment on its own. When the four items below appear in the written quote, the lighting becomes verifiable.

Average illuminance
The target average lux on the court surface and the points at which it will be measured are stated in the quote.
Uniformity ratio
The ratio of the minimum illuminance to the average is requested. That ratio makes the dark zones in the corners visible.
Floodlight position
It is verified that the poles sit outside the court and that the lower face of the fixture achieves 6 m.
Glare control
The optical design is required not to direct light straight into the player line of sight. That condition follows from the visibility requirement in the rule book.

Groundwork

Groundwork, Drainage and Surface Tolerances

The item that determines the life of a court is the one nobody sees. Where the supporting layer is prepared badly, the outcome does not change however good the glass and the structure are.

Groundwork, compaction of the supporting layer

Measurable commitments

Flatness tolerance
3 mm under a 3 m straightedge
Cross fall, undrained
%1
Surface material
concrete, synthetic or artificial turf
Surface colour
green, blue or terracotta

Both tolerances are stated in writing in the quote and verified with a straightedge at handover. The measurement is taken in the presence of the court owner and the result is delivered in writing. Numeric commitments for groundwork are rarely given in the market; a commitment that cannot be measured also cannot be compared.

The supporting layer is prepared as a concrete slab or as asphalt. The choice follows the ground investigation, the level difference and the budget. In both solutions the decisive factors are the flatness of the surface and the removal of water from it.

The rule book gives a measurable tolerance for flatness. Measured with a three metre straightedge, the internal level difference must be less than three millimetres. That ratio corresponds to one in a thousand and is verified with a straightedge rather than by eye.

On surfaces without a drainage line the maximum cross fall is %1, applied from the centre towards the outer edges. Above that value ball rebound is disrupted; below it water stands on the surface.

Three items are measured on site during the survey: the existing level difference, the bearing capacity of the ground and the point at which water can be discharged. Where an existing five a side pitch or tennis court is to be converted, these three measurements determine directly whether conversion is possible.

The choice between a concrete slab and asphalt is not only about cost. A concrete slab offers higher dimensional stability and lasts longer in conversions. Asphalt is laid faster and shortens the application period over large areas.

Compaction is the invisible yet most decisive operation in groundwork. Inadequately compacted fill settles within a few years and produces depressions beyond tolerance at the surface. Such settlement can afterwards be corrected only by removing the surface.

Layer build up from the bottom upwards

A court surface is not a single layer. Each of the four layers below performs a distinct function, and where one is omitted the result appears at the surface.

Prepared fill
Topsoil is stripped, crushed stone fill is laid in stages and each stage is compacted separately. Bearing capacity is achieved in this layer.
Supporting slab
A concrete slab is cast or asphalt is laid. Flatness and cross fall are established in this layer; later layers do not correct an error made here.
Surface covering
Artificial turf or a synthetic covering is laid. Roll seams are joined and no level difference is left in the playing area.
Sand infill
Silica sand is spread in stages and brushed after each stage. Fibre uprightness and ball rebound are set by this layer.

Process

The Construction Process From Survey to Handover

The five stages below apply to an outdoor court. In indoor systems the roof fabrication comes into play and the period lengthens.

  1. Week 1

    Survey and ground investigation

    The plot is measured on site. Level difference, bearing capacity, drainage and vehicle access are assessed. Where an existing pitch is to be converted, flatness is checked with a straightedge. Court orientation and the layout plan are determined at this stage.

    Stage output Measured site plan and a proposed layout

  2. Weeks 1 – 2

    Written quote and contract

    A written quote is prepared item by item from the survey result. Glass thickness, surface grade, lighting layout and handover period are stated explicitly in the quote. The figure becomes final at this stage. The payment schedule and handover date are set out in the contract.

    Stage output Itemised written quote and signed contract

  3. Weeks 2 – 3

    Groundwork and supporting surface

    The supporting slab is cast or asphalt is laid. The drainage line is run, a cross fall of %1 is applied and flatness is held within 3 mm under a 3 m straightedge. This stage determines the life of the court. With a concrete solution the curing period is added to the schedule separately.

    Stage output Supporting surface verified with a straightedge and a drainage line

  4. Week 4

    Structure and glass installation

    The galvanised steel frame is erected. Tempered glass panels and mesh fencing are installed. The layout rule is applied: horizontal wires inside, vertical wires outside. Fixing points and panel plumb are checked during installation.

    Stage output Erected structure, glass walls and mesh fencing

  5. Week 5

    Surface, net, lighting and handover

    Artificial turf is laid and silica sand infill is applied. Lines are marked at 5 cm width, the net is set to a centre height of 0,88 m and the floodlights are commissioned. Flatness and dimensions are verified on site at handover.

    Stage output A court ready for play and an on site handover measurement

The permit process falls outside this schedule and rests with the investor. Construction begins once the necessary permits have been obtained. Two items extend the schedule: weather conditions and concrete curing time. Both arise during the groundwork stage and are stated separately in the written quote.

Glass and mesh installation, fourth stage

Items verified on site at handover

Handover is a measurement exercise rather than an opinion. The items below are measured in the presence of the court owner and the results are delivered in writing.

  • Court internal dimensions 20 × 10 m within a tolerance of %0,5
  • Surface flatness measured with a straightedge, tolerance 3 mm under a 3 m straightedge
  • Cross fall and discharge of water from the surface
  • Net height 0,88 m at the centre and 0,92 m at the ends
  • Line width 5 cm and service line position
  • Glass panel plumb and junction protection
  • Mesh layout: horizontal wires inside, vertical wires outside
  • Operation of the lighting and floodlight positions

Conversion

Converting an Existing Five a Side Pitch or Tennis Court to Padel

A disused five a side pitch or tennis court can be converted into a padel court. Three measurements determine whether the conversion is possible.

Aerial view, court and perimeter allowance

Conversion costs less than new construction because part of the groundwork already exists. The saving depends on the condition of the surface and is established by measurement during the survey.

The first measurement is area. A padel court is built to internal dimensions of 20 × 10 m with a clear area around it. Because the recommended total dimension is 28 × 18 m, a standard five a side pitch usually takes one court, while wider pitches take two.

The second measurement is the surface. The existing concrete or asphalt is checked with a three metre straightedge. If flatness meets the 3 mm under a 3 m straightedge tolerance the surface is retained; if not, a levelling layer is applied or the surface is renewed.

The third measurement is drainage. It is confirmed that water leaves the surface and the cross fall is held at %1. Existing lighting poles are also assessed; if the lower face of the fixture sits below 6 m, the poles are replaced.

The steel frame and mesh of a five a side pitch do not meet the requirements of a padel court. On a padel court the side walls are tempered glass and the structure is calculated for that load. The existing cage is therefore not retained.

Because five a side dimensions vary from site to site, how many courts will fit is established only by on site measurement. Layout plans prepared without allowing for the perimeter area do not hold in practice and have to be changed during construction.

Most of the saving in a conversion comes from the groundwork. Where excavation, fill and the supporting slab already exist, the investment figure falls markedly. If the surface has to be renewed, the saving is limited to landscaping and electrical infrastructure.

A tennis court conversion proceeds differently from a five a side pitch. The concrete or asphalt surface of a tennis court is usually close to the flatness tolerance and needs little levelling. Its perimeter allowance is narrow, however, so the safety area is rearranged.

Before a conversion decision is taken, the permit status of the existing structure is also checked. Where a court is to be built inside an enclosed building, the occupancy permit and the clear ceiling height are assessed together.

What is retained and what is renewed in a conversion

The distinction below is finalised by the survey result. An item listed as retained moves to the renewed list if it fails the measurement tolerance.

Usually retained

  • The supporting concrete or asphalt surface, if it meets the flatness tolerance
  • The drainage line, if the fall is adequate
  • The main electrical supply and distribution board
  • Perimeter fencing and the car park layout

Renewed in every case

  • The steel structure and the tempered glass side walls
  • The surface covering, artificial turf and silica sand infill
  • The net, posts and line markings
  • The floodlights, including poles where the mounting height is inadequate

Is your existing pitch suitable for conversion

Surface flatness, drainage and perimeter allowance are measured on site. The result is reported in writing the same day.

Message Us on WhatsApp Request a Padel Court Quote

Regulation

Permits, Approvals and TTF Adequacy Criteria

The two questions investors find hardest to answer sit here: which permits are required and how many stars the facility will receive. They are separate processes and neither replaces the other.

What the federation certifies and what it does not

The federation adequacy instruction is not an approval document covering the planning, construction, permitting or structural safety of padel facilities. The instruction states this explicitly in its own text.

The federation accepts no liability for planning, construction, structural suitability or safety in use. Liability in those areas rests with the investor and the operator.

For that reason the phrase federation approved court is not used on this page. The correct wording is that construction follows the adequacy criteria. The permit process is conducted with the municipality and the relevant authorities.

The adequacy assessment looks at the whole facility. The technical properties of the court are assessed in section A, the changing and booking arrangements in section B, and tournaments and social areas in section C.

That distinction has a practical consequence for the investor. However well the court is built, the star rating falls if changing rooms and parking are missing. The facility plan is therefore worked out before the court is ordered.

How the scoring works

Assessment is made out of one hundred points. A minimum of 50 points is required for the adequacy certificate.

A · Technical criteria
At least 35 points are compulsory from this section.
60
B · Facility and operating criteria
Changing rooms, showers, parking and operating items are assessed.
25
C · Organisation and development
Tournaments, coaching and club activities are assessed.
15

If any single criterion in section A scores zero, the adequacy certificate is withheld regardless of the total score. Each of the nine technical criteria is a separate pass threshold.

Section A technical criteria

Code Criterion Points Requirement for full marks
A1 Court dimensions 8 full compliance with 20 × 10 m
A2 Glass systems 8 12 mm tempered, certified and gap free
A3 Mesh and fencing 6 Gap free, horizontal wires inside, vertical wires outside, certified
A4 Surface quality 7 Suited to padel and certified
A5 Lighting 7 LED, shadow free, no intrusion into the court
A6 Ceiling height 6 8 m and above
A7 Safety and accesses 7 Non slip surface, impact absorbing door and net post
A8 Net 6 Correct heights, no gap between post and fence
A9 Out of court area per court 5 above 4 m and safe

Star rating thresholds

Points Result
⁦0 – 49⁩ No certificate issued
⁦50 – 64⁩ 1 star padel court
⁦65 – 75⁩ 2 star padel court
⁦76 – 85⁩ 3 star padel court
⁦86 – 95⁩ 4 star padel court
⁦96 – 100⁩ 5 star padel court

Permit and approval items

The amounts below are paid to the relevant authorities and fall outside our quote bands. The process takes ⁦3 – 6 ay⁩ and construction begins only once the permits are in place.

  • Business opening and operating licence ⁦5.000 – 20.000 ₺⁩
  • Building permit, for enclosed construction ⁦30.000 – 80.000 ₺⁩
  • Fire safety compliance certificate ⁦5.000 – 15.000 ₺⁩
  • Directorate General of Sports registration ⁦3.000 – 8.000 ₺⁩
  • Architectural and engineering signature fees ⁦15.000 – 40.000 ₺⁩
  • Total ⁦58.000 – 163.000 ₺⁩

The amounts vary with the municipality and the scope of the project. Which documents will be required is assessed against local regulation during the survey. A building permit is usually not required for an outdoor court, while enclosed systems require both a building permit and fire safety compliance.

Separate from scoring: compulsory facility requirements

The adequacy instruction also makes the facility requirements of the Private Physical Education and Sports Facilities Regulation compulsory. The items below earn no points, but the process does not advance without them.

Changing room, usable area
8 m²
Number of changing rooms
at least two, for women and men
Rest lounge
15 m²
Showers and toilets
at least two each, for women and men
Changing room temperature
18 °C
Sports area temperature
18 °C and above
Court surface
concrete, synthetic or artificial turf

Showers and toilets are located inside the changing rooms. Hot water is supplied to the showers throughout operating hours. Sharp edges are covered with impact softening material and no poles, pits or trees are left around the court.

Who it is for

For Investors, Hotels, Municipalities, Residences and Clubs

The same court raises different questions for different buyers. The five headings below frame the requests received most often, and each lists the three topics raised first during a survey.

Facility investor

The priority is the payback period. Court count, occupancy expectations and operating cost are assessed together. The tool in the investment section gives an explicit model of that calculation. As the number of courts rises the groundwork cost per court falls, so the scale decision comes before the cost decision.

Raised first during the survey

  • Whether the land is owned or leased
  • Target opening date
  • Whether social areas and parking are in scope
Court count and payback

Hotel and resort

The priority is guest experience and visual coherence. The panoramic system keeps the spectator view open. The surface colour is chosen from green, blue or terracotta to suit the architectural language of the property. Scheduling construction outside the season allows it to finish without closing the operation.

Raised first during the survey

  • Suitable seasonal window for construction
  • Relationship of the court to the existing landscape
  • Whether night use is planned
Panoramic system and colour match

Municipality and public sector

The priority is compliance with the tender specification and documentation. Items such as glass thickness, surface certification and ceiling height are written numerically into the specification and verified at handover. The clauses in the specification section are published in a form that can be used directly for that purpose.

Raised first during the survey

  • Minimum technical values sought in the specification
  • Inspection and acceptance measurement method
  • Access arrangements for disabled users
Specification and verifiability

Residential development

The priority is the space constraint and noise. Because the recommended total dimension for a single court is 28 × 18 m, the layout plan is worked out at an early stage. Proximity of the blocks, lighting orientation and hours of use are assessed together with the management plan.

Raised first during the survey

  • Net dimensions of the available area
  • Distance to the nearest residential facade
  • Hours of use and the management decision
Space constraint and layout

Sports club

The priority is tournament suitability and the adequacy score. On an indoor court, a ceiling of 8 m and above together with 12 mm glass are the two items that earn full marks in the technical criteria. Where spectator layout and video recording are planned, the lighting design is set up accordingly from the outset.

Raised first during the survey

  • Target star rating
  • Expected spectator capacity
  • Video recording and broadcast requirements
Tournaments and adequacy score

These five headings are not a closed list. Requests from schools, universities, factory campuses and tourism facilities are assessed within the same framework. What matters is not who the buyer is but the dimensions of the area and the intended pattern of use.

Maintenance

Maintenance, Service Life and Renewal Cost

The life of a padel court depends on the intensity of use and on the maintenance regime. The five maintenance items and the measurements behind a renewal decision are set out below.

The five maintenance items

Alongside each item, how that item is verified is written separately. Maintenance is a measurement list rather than a service list.

  1. Surface and sand infill

    Silica sand holds the fibres upright and regulates ball rebound. As the sand level falls the fibres flatten, rebound is disrupted and wear accelerates. Brushing redistributes the sand and lifts the fibres.

    How it is checked Sand level and fibre uprightness are checked on site.

  2. Glass and structure

    The fixing points, gaskets and clamps of the tempered glass panels are checked periodically. On galvanised steel, corrosion starts most often near the surface and at welded joints.

    How it is checked Fixing tightness and coating integrity are inspected.

  3. Net and lighting

    Net height drops over time and the centre measurement is reset against 0,88 m. The luminous flux of LED fixtures falls with operating hours; the measurement is taken in lux. A drop in flux cannot be read from the wattage.

    How it is checked Net height and the lux level on the court surface are measured.

  4. Drainage and surroundings

    That water leaves the surface is checked at the start of each season. Where the drainage line blocks, water collects at the edges, the sand infill shifts and localised settlement begins at the surface. Leaf and dust build up produces the same result.

    How it is checked Whether water stands on the surface after rainfall is observed.

  5. Doors and safety equipment

    The hinges and fixings of the access doors are tightened periodically. Impact absorbing coverings are replaced when they wear. Because this item is assessed under the safety criterion in the federation scoring, its maintenance also affects certificate renewal.

    How it is checked Door swing direction and impact absorbing covering are checked.

Surface renewal cost

When the surface is renewed the structure and glass are retained; only the covering and the infill change. The cost varies with the surface grade selected. The renewal decision is taken by measurement rather than by calendar. Where the fibres have flattened and brushing no longer restores rebound, the covering has reached the end of its life.

  • Surface renewal, single court ⁦250.000 – 900.000 ₺⁩

Why we do not publish a maintenance schedule

Brushing frequency and surface life vary with the intensity of use, the climate and the surface grade. Because we hold no verified source for those values, no general purpose schedule is published. The maintenance plan is set for each facility from measurements taken after construction.

Regions

Padel Court Construction in Ankara and Across Turkey

The head office is in Ankara and construction is carried out across Turkey. Geography is a technical variable, not only a distance.

Steel structure and canopy roof, during play

Service scope

Head office
Ankara
Construction area
Nationwide in Turkey
Survey
free and without obligation
Quote
written and itemised

In Central Anatolian conditions the freeze and thaw cycle is decisive. Keeping water out of the supporting layer and keeping the drainage working determine the life of a court in that region directly. The cross fall is held at %1 and the discharge point is identified during the survey.

In coastal provinces salt laden air brings corrosion to the front. Galvanised coating thickness and the grade of the fixings are assessed separately in those regions. Because corrosion resistance determines service life on an outdoor court, that item is stated in writing in the quote.

The permit process varies from municipality to municipality. Which documents are required and which authority is competent differ under local regulation, so the permit items are assessed on site during the survey.

The logistics of haulage and the installation crew affect the handover period. In distant provinces the construction schedule is set by crew planning and is given as a date in the written quote.

Snow load changes the structural calculation directly in provinces where an indoor court is planned. In Eastern and North Eastern Anatolian conditions the roof structure is calculated separately and the cover options narrow. That calculation is an engineering item independent of the court cost.

Wind load is decisive on outdoor courts. On elevated terrain and along the coast the glass forms an uninterrupted screen, so post spacing is reduced and section sizes are increased. The same system is not built with the same structure on every plot.

In hot climate regions the surface colour and shading come to the front. A dark surface raises the surface temperature. The choice among the green, blue or terracotta permitted by the rule book is made with that condition in mind.

The form of a public tender specification also varies by region. Some authorities ask only for dimensions and material grades, while others refer directly to the federation criteria. In both cases the quote is prepared item by item and in the same format.

Company

Padex as a Padel Court Contractor

This page describes method rather than claims. The six principles below are applied at the quotation, construction and handover stages. No information that cannot be verified appears on this page.

  1. Prices are published

    Price bands and cost items appear openly on this page. The date of the last update is stated visibly, and the bands are reviewed every three months.

  2. Quotes are itemised

    Glass thickness, surface grade, lighting layout and handover period are stated separately in the written quote. That makes a quote comparable with another quote.

  3. Tolerances are measurable

    The flatness value of 3 mm under a 3 m straightedge and the cross fall of %1 are written into the quote and verified with a straightedge at handover. No commitment is given that cannot be measured.

  4. Sources are cited

    The technical values on this page are taken from FIP Rules of Padel and TTF Padel Court Sporting Suitability Directive. No unverified value is published.

  5. No claims are made

    No certification is claimed without a document number. The phrase federation approved court is not used, because the federation scores sporting adequacy and does not approve construction.

  6. The unknown is written as unknown

    Values for which we hold no verified source are not published. The lux classes in the lighting section and a general purpose maintenance schedule are therefore absent from this page, and both absences are stated explicitly.

Company details

Company
Padex
Head office
Ankara
Service area
Nationwide in Turkey
Phone
0312 911 88 17
Mobile
0533 269 46 07
WhatsApp
0533 269 46 07
E-mail
info@padelkortmaliyeti.com.tr
Working hours
Monday – Saturday ⁦09:00 – 19:00⁩
Address
Söğütözü Mah. Eskişehir Yolu 6. km No: 6, Armada İş Merkezi A Blok Kat: 14, 06520 Çankaya / Ankara

Work we carry out

The scope of work is limited to the items below. Work outside that scope is referred elsewhere rather than presented as undertaken.

  • Turnkey construction of outdoor and indoor padel courts
  • Conversion of an existing pitch or tennis court to padel
  • Surface renewal, covering and sand infill replacement
  • Court lighting and floodlight layout installation
  • Layout planning for facilities with several courts

Outside our scope

  • Conducting permit and approval applications
  • Construction of changing rooms, reception and social areas
  • Car park and landscaping works
  • Facility operation and booking system installation

Specification

Commitments a Written Quote Should Contain

The list below is a checklist. Whichever contractor is asked for a quote, having these items stated in writing makes quotes comparable.

Item Commitment How it is verified at handover
Court internal dimensions 20 × 10 m, tolerance %0,5 Tape measured in both directions
Surface flatness 3 mm under a 3 m straightedge Three metre straightedge and shim
Cross fall %1 on an undrained surface Levels taken with a level or laser
Glass thickness 12 mm tempered, certified and gap free Certificate and calliper
Mesh diagonal 5 – 7,08 cm Measured with a calliper
Mesh layout horizontal wires inside, vertical wires outside Verified visually
Net height centre 0,88 m, ends 0,92 m Tape measured at three points
Line width 5 cm Measured with a tape
Clear height minimum 6 m on an indoor court Laser distance meter
Floodlight lower face minimum 6 m Laser distance meter
Safety area minimum 3 m, recommended 4 m Tape measured on all four sides
Access opening between 1,05 × 2,00 m and 2,20 × 2,20 m with a single access Measured with a tape
Access protection impact absorbing covering at least 2 cm Calliper and visual check
Service line position 6,95 m from the net axis Tape measured in both halves
Galvanised coating hot dip, thickness stated in microns Coating gauge and certificate

If some of these items are absent from a written quote, the two quotes may not describe the same work. The list draws on FIP Rules of Padel and TTF Padel Court Sporting Suitability Directive. That is also why it is published on this page: once the buyer holds a measurable checklist, quotes become comparable.

System types

The images below show the system types. The captions state the technical feature only.

Outdoor system, tempered glass and mesh
Panoramic system, stepless glass
Aerial view, court and perimeter allowance
Indoor system, tensile membrane roof
Substrate preparation and compaction
Concrete foundation and anchors

Video

Court and Facility Views

The clips below show the court layout and the scale of a facility from above. They carry no sound and play only on request.

Multi court facility, aerial view The clip shows several courts arranged on one site, the shared areas and the car park layout. How the perimeter area is shared as the court count rises can be followed here. 19 seconds
Single court and perimeter allowance The court itself occupies 200 m², and with the clear area around it the recommended total dimension becomes 28 × 18 m. The clip shows the difference between those two areas from above. 12 seconds

These clips are used to explain system types and layout scale. Footage of completed projects will be added as work is delivered.

FAQ

The Questions Investors Ask First

The answers below draw on the same sources as the rest of the page. When a standard or a price changes, the answers change with it.

Price and cost

How much does a padel court cost?
Turnkey bands run from ⁦700.000 – 1.000.000 ₺⁩ for an outdoor standard court and ⁦900.000 – 1.300.000 ₺⁩ for an outdoor panoramic court. An indoor court with a membrane roof falls within ⁦1.300.000 – 1.900.000 ₺⁩ and a sandwich panel building within ⁦1.900.000 – 2.900.000 ₺⁩. Land cost, permit fees, landscaping and transport fall outside these bands.
Why are prices given in Turkish Lira rather than euro?
Prices in the market are usually published in euro, and that approach leaves the entire exchange rate risk with the buyer. On this page the bands are given in Turkish Lira. No foreign currency equivalent is published, because the rate changes daily and a printed figure becomes wrong within a short time. The date of the last update is stated visibly on the page.
What is included in that figure?
Galvanised steel structure, tempered glass panels and mesh fencing, artificial turf surface, silica sand infill, net and posts, labour and installation are inside the bands. Land cost, permit fees, landscaping, transport and buildings outside the court are excluded.
Does the cost fall if several courts are built?
When several courts are built on the same site, transport, crew time and groundwork are shared and the cost per court falls. The calculator applies that scale effect according to the number of courts.
How much does the surface grade change the price?
Pile height, fibre structure and stitch density of the artificial turf determine both playing performance and cost. The gap between the economy grade and the tournament grade can exceed a factor of two per square metre. Because a single court covers two hundred square metres, that gap is clearly visible in the total.
How often are the published prices updated?
The bands are reviewed every three months and the last update date is written visibly in the pricing section. An out of date price is worse than publishing no price at all.

Dimensions and land

How many square metres is a padel court?
The internal dimensions of the court are 20 × 10 m and its area is 200 m². The rule book allows a tolerance of %0,5 on that dimension and requires the two halves of the court to be perfectly symmetrical.
How much land is required for a padel court?
The court itself occupies 200 m², but a clear safety area is required on all four sides. At the minimum dimension the total is 26 × 16 m, that is 416 m²; at the recommended dimension 28 × 18 m, that is 504 m². Reception, changing rooms and parking fall outside this calculation.
Is there a single player padel court dimension?
A single player court dimension is not defined in the rule book. The twenty metre by six metre dimension commonly used in the market is an industry convention and not a federation rule.
How does the land requirement change with several courts?
Where courts are built side by side, part of the perimeter area is shared and the land requirement per court falls. The exact dimension is set by the layout plan; level difference and access routes are included in that plan during the survey.
What ceiling height is required on an indoor court?
A clear height of at least 6 m is required across the whole court, and 8 m is recommended for new facilities. In the federation assessment 8 m and above scores 6 / 6, while between 6 m and 8 m scores 3 / 6. A height below 6 m scores zero and leads to the certificate being withheld.

Systems and materials

What is a panoramic padel court?
The rule book permits two variants for the side wall. In the stepped system a two step wall is placed at each end. In the panoramic system 3 × 4 m of uninterrupted glass is used in the end zone and there are no steps. Panoramic is a defined structure, not a marketing adjective.
What is the difference between ten millimetre and twelve millimetre glass?
In the federation assessment, certified and gap free twelve millimetre tempered glass scores 8 / 8, while ten millimetre is scored 5 / 8 under the same conditions. Uncertified or gapped glass scores zero and on its own leads to the certificate being withheld.
Should a standard or a panoramic system be chosen?
The panoramic system uses single pane glass, so it requires more tempered glass and a stronger structure and costs more as a result. Because the spectator view remains uninterrupted, tournament and club facilities prefer it. Where budget is the priority, the stepped system is appropriate.
Should a membrane roof or a sandwich panel be preferred?
A tensioned membrane roof is installed faster and provides year round use at a lower cost. A sandwich panel building brings thermal insulation and climate control, while installation time and cost both increase.

Detailed cost breakdown

What colour may the court surface be?
The rule book permits green, blue or terracotta for the surface. The surface is a single colour throughout and is clearly distinct from the wall colour. Lines are chosen to contrast with the surface, preferably white or black.
What should the mesh fencing be like?
The mesh diagonal falls within 5 – 7,08 cm, wire thickness of 2 – 3 mm is recommended and it does not exceed 4 mm. The layout rule is explicit: horizontal wires inside, vertical wires outside. The tensioning mechanism is positioned outside the court and protected.

Process and regulation

How long does padel court construction take?
On an outdoor court the period from groundwork to handover is three to five weeks. An indoor court with a membrane roof takes six to nine weeks and a sandwich panel building ten to fourteen weeks. The permit process falls outside that schedule.
Is a permit required for a padel court, and which documents are obtained?
A business opening and operating licence, a fire safety compliance certificate, Directorate General of Sports registration and professional signatures are required. Enclosed construction additionally requires a building permit. The process takes three to six months and the fees are paid to the relevant authorities. Which documents are required varies from municipality to municipality.
How is the federation adequacy certificate obtained?
Assessment is made out of 100 points and a minimum of 50 points is required for the certificate. The technical criteria section carries 60 points and at least 35 points from that section are compulsory.
How many stars will my facility receive?
The star rating follows the point band. Fifty to sixty four points corresponds to one star, sixty five to seventy five to two stars and seventy six to eighty five to three stars. Eighty six to ninety five points earns four stars and ninety six and above earns five. If any technical criterion scores zero, the certificate is withheld regardless of the total.
Is there such a thing as a federation approved padel court?
The adequacy instruction is not an approval document for the planning, construction, permitting or structural safety of facilities, and the federation accepts no liability in those areas. For that reason the phrase federation approved court is not used. The correct wording is that construction follows the adequacy criteria.

Conversion, investment and maintenance

Can I convert my existing five a side pitch into a padel court?
It is possible where the dimensions and groundwork are suitable, and it costs less than new construction. Three measurements are decisive: whether the area meets the 28 × 18 m dimension, whether the existing surface meets the 3 mm under a 3 m straightedge flatness tolerance and whether the drainage works. The steel structure and cage of a five a side pitch are not retained, because they do not carry the glass load of a padel court.
How many years does a padel court investment take to pay back?
The industry frequently states twenty four to thirty six months, but operating data published at the scale of Turkey does not confirm that period. The large majority of successful facilities recover the investment within four to six years. That period covers the whole facility; the gross payback on the court investment itself can be calculated with the tool in the investment section.
How many watts should the lighting be?
The question should be asked in the right unit. Watts state only the electricity consumed, while the brightness a player sees is measured in lux. The rule book requires the lower face of the floodlight to sit at least 6 m above the surface. Facilities used for television broadcast require at least 1000 lux of vertical illuminance.
How is a court maintained?
Maintenance consists of five items: surface and sand infill, glass and structure, net and lighting, drainage, and doors and safety equipment. As the sand level falls the fibres flatten and rebound is disrupted; brushing redistributes the sand. Because the frequency varies with the intensity of use, no general purpose schedule is published and the plan is set for each facility.
How much does surface renewal cost?
When the surface is renewed the structure and glass are retained and only the covering and infill change. For a single court the figure falls within ⁦250.000 – 900.000 ₺⁩ and is set by the surface grade selected.

Quote

Free Site Survey and Quote Request

The survey is free of charge and carries no obligation. A response follows within one working day of the form being sent.

Details such as the land situation, an existing pitch or a target opening date speed up the survey.

Full name and phone number are required.

Direct contact

WhatsApp
0533 269 46 07

The phone and WhatsApp line is open Monday to Saturday between ⁦09:00 – 19:00⁩.

What happens after the request is sent

The process runs in four steps. No payment or binding commitment is requested at any step.

  1. Same day response

    The request is answered by phone or e-mail. The land situation, the target number of courts and the opening date are discussed briefly.

  2. Survey appointment

    The plot is measured on site. Level difference, bearing capacity, drainage and vehicle access are assessed. The survey is free of charge.

  3. Written quote

    An itemised written quote is prepared after the survey. Glass thickness, surface grade, lighting layout and handover period each appear separately in the quote.

  4. Contract and schedule

    If the quote is accepted, the payment schedule and handover date are set out in the contract. Construction begins once the necessary permits are in place.